Comdial 8024S Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 438
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
3.3.4 Defaulting The Stations
Description: Returns the station configuration features to factory settings.
To Program: 1. Press INTERCOM, dial # 746. “CONFIG. MODE”
2. Dial 50. “STATION DEFAULT”
3. Dial 00 to default station ports system-wide
—OR—
select individual station port to be defaulted:
— Station 10–57 = Dial 10–57.
4. Dial for next station to default
—OR—
dial ✳✳for configuration mode or SPEAKER to quit.
3.3.5 Defaulting The Button Assignments
Description: Returns the button mapping of individual stations to its factory setting.
To Program: 1. Press INTERCOM, dial # 746. “CONFIG. MODE”
2. Dial 56. “BUTTON MAPPING”
3. Dial 01. “BUTTON DEFAULT”
4. Select station ports to be defaulted
—Station 10–57 = Dial 10–57.
5. Dial for next button mapping feature
—OR—
dial ✳✳for configuration mode or SPEAKER to quit.
3.3.6 Defaulting The Toll Restriction Tables
Description: The system defaults two toll restriction tables with preprogrammed values and assigns
them to the lines. You need only to assign them the stations to put them into effect. The
preprogrammed values are as follows:
Table 1 (deny) Table 2 (allow)
Entry 1 = 1 Entry 1= 1800
Entry 2 = 976 Entry 2 = 911
Entry 3 = 411
Entry 4 = 0
These values will provide satisfactory system performance in a broad range of site
applications; however, they can be changed as needed to meet different toll restriction
needs.
To Program: 1. Dial 70 “DEFAULT TOLL”
2. Press # to default toll tables
3. Dial for configuration mode or SPEAKER to quit.
Digital Telephone System IMI66–107
3 – 14 System Programming
Page view 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 437 438